Maryland Fire Offers Services for your SCBA

To ensure that your Self-contained Breathing Apparatus offers the maximum operating performance and safety, Maryland Fire Equipment Corporation offers inspection, testing, and repairs for most SCBA product lines.

Calibration
PosiChek is the only breathing machine that meets the stringent requirements specified by NFPA 1852. NFPA 1852 mandates that all compliant SCBA must be tested on a calibrating breathing machine at least once per year after being put into service.

Cylinder Requalification
Requalification of SCBA cylinders is required by DOT and NFPA 1852 with a frequency that depends on the design of the cylinder. The SCBA cylinder requalification process includes an internal and external visual inspection. All-metal cylinders are requalified every 5 years and composite cylinders need to be requalified every 3 years.